Edition 11/2007 - V02 R01-S02 Stock no.: 669712
PORTABLE DATA RECORDER
HMG 3000
User Manual
Vue de la page 0
1 2 3 4 5 6 ... 75 76

Résumé du contenu

Page 1 - HMG 3000

Edition 11/2007 - V02 R01-S02 Stock no.: 669712 PORTABLE DATA RECORDER HMG 3000 User Manual

Page 2 - HMG 3000 Page 2

HMG 3000 Page 10 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 4.2 Connectors A B C D

Page 3 - Table of Contents

HMG 3000 Seite 11 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 4.3 Switching the HMG 3000 On When starting the unit up for the first time the

Page 4 - HMG 3000 Seite 4

HMG 3000 Seite 12 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Extras — menu featuring the stopwatch, among other things plus a function for

Page 5 - HMG 3000 Seite 5

HMG 3000 Seite 13 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 5 Getting Started Guide This Getting Started Guide outlines the basic steps

Page 6 - HMG 3000 Seite 6

HMG 3000 Page 14 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 When HSI sensors featuring automatic sensor detection are used, the HMG automatic

Page 7 - 3 Technical Safety

HMG 3000 Page 15 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The HMG now shows the measured values in the 7-segment display panes. Depending o

Page 8 - HMG 3000 Page 8

HMG 3000 Page 16 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 In the Recording option line, select End when time has elapsed in the same manner

Page 9 - 4 Starting the HMG 3000 Up

HMG 3000 Page 17 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6 Detailed Operating Instructions 6.1 Settings Menu Submenus of the Settings men

Page 10 - 4.2 Connectors

HMG 3000 Page 18 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 In the Mode menu you now have the option of Automatic detection (HSI) and Manual.

Page 11 - HMG 3000 Seite 11

HMG 3000 Page 19 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 A drop-down list is also provided for selecting the Unit (of measurement). You a

Page 12 - HMG 3000 Seite 12

HMG 3000 Page 2 Edition 11/2007 - V02 R01-S02 Stock no.: 669712

Page 13 - 5 Getting Started Guide

HMG 3000 Page 20 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Example: For both 100 bar pressure transmitters there is a differential measurem

Page 14 - HMG 3000 Page 14

HMG 3000 Page 21 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Connect the pressure transmitter hydraulically so that the two instruments are su

Page 15 - HMG 3000 Page 15

HMG 3000 Page 22 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 In order to measure the flow rate using a differential pressure measurement at a

Page 16 - HMG 3000 Page 16

HMG 3000 Page 23 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Input channels I and J are for digital signals. As the input signal you can choos

Page 17 - 6.1 Settings Menu

HMG 3000 Page 24 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Examples of frequency measurement: 1) You would like to measure a frequency up t

Page 18 - HMG 3000 Page 18

HMG 3000 Page 25 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 If you have selected counter pulses as the input signal, and have returned to the

Page 19 - HMG 3000 Page 19

HMG 3000 Page 26 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 You should set this value as close as possible to the expected power value to get

Page 20 - HMG 3000 Page 20

HMG 3000 Page 27 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.1.2 Changing Display Settings The next submenu of the Change Display Settings

Page 21 - HMG 3000 Page 21

HMG 3000 Page 28 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The screenshots at the right show the measured values of four sensors when select

Page 22 - HMG 3000 Page 22

HMG 3000 Page 29 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.1.3 Zeroing Measurement Channels You can rezero the measurement channels in th

Page 23 - HMG 3000 Page 23

HMG 3000 Seite 3 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Table of Contents 1 Tasks and Functions of the HMG 3000 ...

Page 24 - HMG 3000 Page 24

HMG 3000 Page 30 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Switching the HMG unit or measurement channels OFF/ON doesn't automatically

Page 25 - HMG 3000 Page 25

HMG 3000 Page 31 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.1.4 Changing the Initial Setup The Change initial setup item is a submenu of t

Page 26 - HMG 3000 Page 26

HMG 3000 Page 32 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Note: Automatic conversion of measured values to the selected unit of measurement

Page 27 - HMG 3000 Page 27

HMG 3000 Page 33 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.1.5 Administer settings (save, load, ...) All of the measurement channel sett

Page 28 - HMG 3000 Page 28

HMG 3000 Page 34 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 In the submenus Load stored settings or Delete stored Settings, you are shown a l

Page 29 - HMG 3000 Page 29

HMG 3000 Page 35 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.2 Recording Menu Here the HMG enables you to perform a measurement for a specif

Page 30 - HMG 3000 Page 30

HMG 3000 Page 36 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Sampling rate This item enables you to set the rate at which the HMG reads a meas

Page 31 - HMG 3000 Page 31

HMG 3000 Page 37 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The sampling rate which can be set is also dependent on the active measurement ch

Page 32 - HMG 3000 Page 32

HMG 3000 Page 38 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Example of Recording a Simple Measurement Curve The settings made for the exampl

Page 33 - HMG 3000 Page 33

HMG 3000 Page 39 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Before doing this, you can have the measurement shown again as a curve (Graph + O

Page 34 - HMG 3000 Page 34

HMG 3000 Seite 4 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 1 Tasks and Functions of the HMG 3000 The HMG 3000 portable data recorder is a

Page 35 - 6.2 Recording Menu

HMG 3000 Page 40 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Measurement Curve with Trigger Measurement curve with trigger is another recordi

Page 36 - HMG 3000 Page 36

HMG 3000 Page 41 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Event: Actuation of button/key The simplest event is actuating a button or key t

Page 37 - HMG 3000 Page 37

HMG 3000 Page 42 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Event: Leaving measurement window This trigger event is very similar to Specific

Page 38 - HMG 3000 Page 38

HMG 3000 Page 43 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Linking Events You also have the option of linking events. Without linking, each

Page 39 - HMG 3000 Page 39

HMG 3000 Page 44 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The next setting parameter for recording a triggered measurement curve is Pre/pos

Page 40 - HMG 3000 Page 40

HMG 3000 Page 45 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Example of an Automatically Triggered Measurement The following occur in a hydr

Page 41 - HMG 3000 Page 41

HMG 3000 Page 46 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 As soon as you confirm saving via OK, measurement is activated, resulting in the

Page 42 - HMG 3000 Page 42

HMG 3000 Page 47 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Event Log The Event Log option enables you to store measured values as a table.

Page 43 - HMG 3000 Page 43

HMG 3000 Page 48 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 • In order to also manually generate a measured value line, set a second event t

Page 44 - HMG 3000 Page 44

HMG 3000 Page 49 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Using the arrow keys of the 5-way navkey, you can select the arrows next to the s

Page 45 - HMG 3000 Page 45

HMG 3000 Seite 5 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 One special feature of the HMG 3000 is its ability to record measurements of the

Page 46 - HMG 3000 Page 46

HMG 3000 Page 50 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The Comment item enables you to enter a text, e.g. a description indicating the o

Page 47 - HMG 3000 Page 47

HMG 3000 Page 51 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.2.2 Viewing Recordings The View recording item in the Recording menu causes a l

Page 48 - HMG 3000 Page 48

HMG 3000 Page 52 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Graph A measurement can also be rendered as a measurement curve. To do this, sel

Page 49 - HMG 3000 Page 49

HMG 3000 Page 53 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Back Back/Esc enables you to return to the previous menu. Automatic: Auto

Page 50 - HMG 3000 Page 50

HMG 3000 Page 54 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Use the ► and ▲ arrow keys while holding the Shift key down to enlarge a portion

Page 51 - HMG 3000 Page 51

HMG 3000 Page 55 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Ruler: When the Ruler is activated, the screen takes on an appearance as shown in

Page 52 - HMG 3000 Page 52

HMG 3000 Page 56 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Tracker: Using the Tracker is similar to using the ruler. The difference is that

Page 53 - HMG 3000 Page 53

HMG 3000 Page 57 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Display all: Display all causes the recording throughout the entire recording per

Page 54 - HMG 3000 Page 54

HMG 3000 Page 58 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 In the list of channels, select a channel to the right next to the box, and confi

Page 55 - HMG 3000 Page 55

HMG 3000 Page 59 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Entering the following new settings for "Sensor measurement 3(1)" would

Page 56 - HMG 3000 Page 56

HMG 3000 Seite 6 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The HYDAC software CMWIN also comes standard with the unit. This software enable

Page 57 - HMG 3000 Page 57

HMG 3000 Page 60 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Table Tables are useful for displaying individual measured values. Select Table

Page 58 - HMG 3000 Page 58

HMG 3000 Page 61 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 The date and Min/Max values can be hidden so as to make tables easier to read. Yo

Page 59 - HMG 3000 Page 59

HMG 3000 Page 62 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.2.3 Deleting Recordings Any recording can be deleted when no longer needed. T

Page 60 - HMG 3000 Page 60

HMG 3000 Page 63 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.3 Extras Menu The following options are available to you in the function bar o

Page 61 - HMG 3000 Page 61

HMG 3000 Page 64 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Update Instrument Software If a firmware update has been transferred to your HMG

Page 62 - HMG 3000 Page 62

HMG 3000 Page 65 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.4 SMART Sensors These are the new generation sensors from HYDAC, capable of out

Page 63 - 6.3 Extras Menu

HMG 3000 Page 66 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.4.2 SMART Sensors Menu You are now in the SMART Sensors menu and can enter set

Page 64 - HMG 3000 Page 64

HMG 3000 Page 67 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 After selecting a recording and the Transfer option, you see the following screen

Page 65 - 6.4 SMART Sensors

HMG 3000 Page 68 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Transfer configuration to sensor This menu enables you to transfer existing SMART

Page 66 - HMG 3000 Page 66

HMG 3000 Page 69 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 6.5 Technical Specifications Sensor Inputs The HMG features: • 4 sensor input

Page 67 - HMG 3000 Page 67

HMG 3000 Page 7 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 2 About Your HMG 3000 2.1 Included with the HMG as Supplied • HMG 3000 • Pow

Page 68 - HMG 3000 Page 68

HMG 3000 Page 70 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 Sampling Rates • Sampling rate: 0.1 ms - 1 min • Sampling rate: 0.1 ms fo

Page 69 - 6.5 Technical Specifications

HMG 3000 Page 71 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 8 Accessories • Pressure transmitters for the following measurement ranges: -

Page 70 - 7 Cleaning

HMG 3000 Page 72 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 • Miscellaneous accessories Stock no. 3304374 Stock des. ZBE 26 (Y adapter,

Page 71 - 8 Accessories

HMG 3000 Page 73 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 9 Connection of HMG Components Pin 1:

Page 72 - HMG 3000 Page 72

HMG 3000 Page 74 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 9.1 Pin assignment Note on H*: Channel H c

Page 73 - HMG 3000 Page 73

Edition 11/2007 - V02 R01-S02 Stock no.: 669712 HMG 3000 Page 75 Power supply connector: JEITA RC-5320 A Pin 1 (outer contact): 0V (GND) Pin 2 (

Page 74 - 9.1 Pin assignment

Edition 11/2007 - V02 R01-S02 Stock no.: 669712 HMG 3000 Page 76 HYDAC ELECTRONIC GMBH Hauptstr. 27 D-66128 Saarbrücken Germany Web : www.hydac.

Page 75 - HMG 3000 Page 7

HMG 3000 Page 8 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 3.1 General Safety Precautions The HMG 3000 series Portable Data Recorder can be

Page 76

HMG 3000 Page 9 Edition 11/2007 - V02 R01-S02 Stock no.: 669712 4 Starting the HMG 3000 Up 4.1 Operating Elements On/Off button Brightness set